Interrupteurs de circuit à défaut d'arc (AFCI) JGAFCI-63

Arc Fault Circuit Interrupters (AFCI)it is assembled by a miniature circuit breaker and an arc fault protection module, and has protection functions such as overload, short circuit, and arc fault protection.

Décrpiton

Introduction


Arc Fault Circuit Interrupters
Arc Fault Circuit Interrupters

Arc Fault Circuit Interrupters (AFCI)it is assembled by a miniature circuit breaker and an arc fault protection module, and has protection functions such as overload, short circuit, and arc fault protection.

    Arc Fault Circuit Interrupters (AFCI) Suitable for communication 50Hz, rated voltage 230V, rated current to 63AIn the following lines, it is used to protect the over current of the lines of buildings and similar purposes, and at the same time, it can detect many fire risks caused by the rupture of electrical devices or the aging of wires in advance, and protect against grounding arc faults, parallel arc faults and series arc faults. To a certain extent, the occurrence of fire safety accidents has been reduced, and the safety of people’s lives and property has been effectively protected.

AFCI Product features


a)Protection contre les surcharges et les retards importants ;

b)Protection contre les surcharges et les courts-circuits ;

c)Instantaneous trip protection ;

d)Series de protection contre les arcs électriques ;

e)Parallel arc fault protection ;

Protection contre les arcs électriques ;

g)Multiples spécifications de courant.

AFCI working  and installation conditions


aTempérature de l'air ambiant

La température de l'air ambiant n'est pas supérieure à+70℃,Pas moins de-35℃,24La moyenne des heures ne dépasse pas+35℃;.

Note: The ambient air temperature is higher+70℃or below-35℃conditions of use AFCI Arc fault protection is off The roader should be negotiated with the manufacturer;

bAltitude:

L'altitude du site d'installation ne dépasse pas 2000m;.

cConditions atmosphériques

L'humidité relative de l'atmosphère est à sa température la plus élevée dans l'environnement+60℃temps pas dépassé 50%, qui peut avoir une phase plus élevée à des températures plus basses à l'humidité, par exemple 20℃temps 90%, pour la condensation occasionnelle due à des changements de température, des mesures de protection doivent être prises ;

dConditions d'installation

Arc Fault Circuit protector The external magnetic field near the installation site should not exceed the geomagnetic field in any direction5Fold; The installation position should be vertical, and the inclination in all directions should not exceed 10°; Installed in a place where there is no shock vibration and no rain or snow Square; Adopt standards TH35-7.5 section steel installation rail installation;

Niveau de pollution électronique : niveau 2

fCatégorie d'installation:ⅢKind ;

gIngression Protection:IP20(Installé dans un coffret de distribution, une armoire de distribution ou une boîte.) IP40);

hwith it N When wiring, the neutral wire must be connected to the mark N Identification of the poles.

Informations sur le paquet standard


 

Dimension du carton (cm) Liste de colisage QTÉ Poids brut (kg)
45,5cm × 23,5cm × 31,5cm  protecteur 120pcs 20 kg