아크 고장 회로 차단기(AFCI) JGAFCI-63

Arc Fault Circuit Interrupters (AFCI)it is assembled by a miniature circuit breaker and an arc fault protection module, and has protection functions such as overload, short circuit, and arc fault protection.

Decrpiton

소개


Arc Fault Circuit Interrupters
Arc Fault Circuit Interrupters

Arc Fault Circuit Interrupters (AFCI)it is assembled by a miniature circuit breaker and an arc fault protection module, and has protection functions such as overload, short circuit, and arc fault protection.

    Arc Fault Circuit Interrupters (AFCI) Suitable for communication 50Hz, rated voltage 230V, rated current to 63AIn the following lines, it is used to protect the over current of the lines of buildings and similar purposes, and at the same time, it can detect many fire risks caused by the rupture of electrical devices or the aging of wires in advance, and protect against grounding arc faults, parallel arc faults and series arc faults. To a certain extent, the occurrence of fire safety accidents has been reduced, and the safety of people’s lives and property has been effectively protected.

AFCI Product features


a) 과부하 및 긴 지연 보호;

b) 과부하 및 짧은 지연 보호;

c) 즉각적인 트립 보호;

d) 직렬 아크 오류 보호;

e) 병렬 아크 오류 보호;

F접지 아크 오류 보호;

g) 다중 현재 사양.

AFCI working  and installation conditions


a주변 대기 온도

주변 공기 온도는 + 70 ℃ 이상, 35 ℃ 이하, 24 시간의 평균은 + 35 ℃를 초과하지 않습니다.

Note: The ambient air temperature is higher+70℃or below-35℃conditions of use AFCI Arc fault protection is off The roader should be negotiated with the manufacturer;

bAltitude:

설치 장소의 고도가 2000m를 초과하지 않아야 합니다.

c대기 조건

대기의 상대 습도는 주변 최고 온도 + 60℃ 시간 50%를 초과하지 않는 상태에서 습도가 낮은 온도에서 더 높은 위상을 가질 수 있으며, 예를 들어 20℃ 시간 90%, 온도 변화로 인해 가끔 응결이 발생할 수 있으므로 보호 조치를 취해야 합니다;

d설치 조건

Arc Fault Circuit protector The external magnetic field near the installation site should not exceed the geomagnetic field in any direction5Fold; The installation position should be vertical, and the inclination in all directions should not exceed 10°; Installed in a place where there is no shock vibration and no rain or snow Square; Adopt standards TH35-7.5 section steel installation rail installation;

전자 오염 수준:2 수준

f설치 카테고리: Ⅲ종류;

g침입 보호: IP20(배전함, 배전 캐비닛 또는 박스에 설치됨) IP40);

hwith it N When wiring, the neutral wire must be connected to the mark N Identification of the poles.

표준 패키지 정보


 

상자 치수(cm) 팩 목록 수량 총 중량(kg)
45.5cm × 23.5cm × 31.5cm  보호자 120개 20kg

지금 문의하세요, 무료 샘플 제공


[wpforms id=”6487″ description=”true”]

Related Products