JGGQ-63 Automatic reset over and under voltage protector adopts the control circuit with high-speed micro-low-power processor as the core, magnetic latching relay as the main circuit, and modularized standard design, when the power supply line appears overvoltage and undervoltage, the protector can quickly and safely cut off the circuit under the continuous high-voltage impact to avoid the occurrence of accidents caused by abnormal voltage sent to the terminal electrical appliances, and when the voltage returns to normal values, the protector will automatically turn on the circuit within the specified time to ensure the normal operation of the terminal appliances in the unattended situation.
Decrpiton
1. Introduction
JGGQ-63 Automatic reset aşırı ve düşük voltaj koruyucusu When the power supply line has overvoltage and undervoltage, the protector can quickly and safely cut off the circuit under the continuous high-voltage impact to avoid the occurrence of accidents caused by abnormal voltage sent to the terminal electrical appliances, and when the voltage returns to normal values, the protector will automatically turn on the circuit within the specified time to ensure the normal operation of the terminal electrical appliances in the unattended situation.
2. Characteristics and use environment
1. When the single-phase line undervoltage occurs, cut off the line, and the single-phase line voltage will return to normal and automatically reset and connect the line after the delay, without manual operation.
2. When there is transient or transient overvoltage in the line, the protector will not malfunction.
3. When the voltage of the line is unstable due to faults such as false contacts, or when the power is suddenly cut off and the call suddenly comes, the protector is not connected to the line.
4. When the line fault voltage is the highest, the protector itself will not be damaged.
5. Withstand impulse voltage: 4kV (in line with the safety standards of Class III electrical appliances).
6. Ambient temperature: -25°C~40°C, relative humidity: 10%~90%, altitude not exceeding 2500 meters, and the place of use should have rainproof facilities.
aşırı ve düşük voltaj koruyucusu of parameters
1. Rated current: 32A, 40A, 50A, 63A
2. Çalışma voltajı: AC230V, 50Hz
3. Aşırı gerilim koruma değeri: AC270V ±5V
4. Düşük gerilim koruma değeri: AC170V ±5V
5. Arıza sonrası sıfırlama süresi: 20 saniye
6. Action time: 0.2 seconds
7. The highest is possiblewithstandAC380V overvoltage.
aşırı ve düşük voltaj koruyucusuof standards
JGJ242-2011 Konut Binalarının Elektriksel Tasarımı için Kod
JGJ/T16-2008
GJBT-672 Konut Binaları Elektrik Tasarım ve Yapım Standart Atlası
GB/T68895.10-2001
Sınıf III elektrikli cihazlar için güvenlik standartlarını karşılar
JB/T12762-2015 《Over Voltage And Under Voltage Protective Device With Auto-Reclosing Function(OUPA)》
aşırı ve düşük voltaj koruyucusu büyüklük

Standart Paket Bilgisi

| Karton Boyut (cm) | Paket listesi | MIKTAR | Brüt ağırlık (kg) |
|---|---|---|---|
| 45,5 cm × 23,5 cm × 31,5 cm | KORUYUCU | 120 adet | 20kg |